STAR Line Mode Command Specifications 3-107
ESC GS / 3 nL nH d1 d2 … dk
[Name] Set user macro 1
[Code] ASCII ESC GS / 3 nL nH d1 d2 ... dk
Hex. 1b 1d 2f 33 nL nH d1 d2 ... dk
Decimal 27 29 47 51 nL nH d1 d2 ... dk
[Defined Area] 1 ≤
n ≤ 64
nH = 0
1 ≤
(nL + nH x 256) ≤ 64
dk = (nL + nH x 256)
0 ≤ d ≤ 255
[Initial Value] No user macro 1 setting
[Function] Sets the user macro 1 of the Auto Logo function.
This command is registered to the non-volatile memory by the “<ESC> <GS> / W” command.
This command is ignored when Auto Logo is being executed.
Registers print data in user macro 1.
A maximum of 64 bytes of data can be registered.
Note that it is prohibited to register Auto Logo command characters in a user macro.
ESC GS / 4 nL nH d1 d2 … dk
[Name] Set user macro 2
[Code] ASCII ESC GS / 4 nL nH d1 d2 ... dk
Hex. 1b 1d 2f 34 nL nH d1 d2 ... dk
Decimal 27 29 47 52 nL nH d1 d2 ... dk
[Defined Area] 1 ≤
nL ≤ 64
nH = 0
1 ≤ (nL + nH x 256) ≤ 64
dk = (nL + nH x 256)
0 ≤
d ≤ 255
[Initial Value] No user macro 2 setting
[Function] Sets the user macro 2 of the Auto Logo function.
This command is registered to the non-volatile memory by the “<ESC> <GS> / W” command.
This command is ignored when Auto Logo is being executed.
Registers print data in user macro 2.
A maximum of 64 bytes of data can be registered.
Note that it is prohibited to register Auto Logo command characters in a user macro.