A SERVICE OF

logo

© Titan Tool Inc. All rights reserved. 5
English
Troubleshooting
IMPORTANT:
The turbine motor can be damaged if not serviced properly.
Have the brushes (Kit P/N 0277243) checked for wear by an
authorized service center every 400 hours.
Clean lters regularly. When the lter warning light comes
on, it is time to clean the lters. Clogged lters cam cause
excessive heat and possibly damage the unit.
For additional troubleshooting information, see the manual
that came with your gun.
Titan 30-Day Satisfaction Guarantee
If, within a 30-day period from the date of purchase, you are not totally satised with a TITAN unit, you may return it for full credit toward
another TITAN product of equal or greater value.
Problem
A. Restricted air ow or no air ow
B. Filter warning light is on
C. The turbine has no power
D. Excessive arcing/sparking in the
turbine
Cause
1. Air ow adjustment knob on the spray gun is
turned o
2. Air lters are clogged
1. Air lters are clogged
1. No power at the power supply
2. Circuit breaker has been tripped.
3. Worn turbine brushes
1. Worn turbine brushes
2. Damaged commutator
Solution
1. Adjust the air ow adjustment knob
2. Clean or replace the lters
1. Clean or replace the lters
1. Check the power supply
2. Reset the breaker. If problem persists, have turbine
inspected at an authorized Titan service center.
3. Have the brushes replaced at an authorized Titan service
center
1. Have the brushes replaced at an authorized Titan service
center
2. Replace the turbine (contact a Titan service technician)
Specications
Air pressure 7.5 psi
Power 120VAC, 60 Hz, 10.7 A
Turbine weight 21.0 lbs
Main hose length 25 ft
Spray gun included Maxum II
Product Registration
Register your product at www.titantool.com
Serial Number Location
xxxxxxx