Evaporator leaving fluid temperature
setpoint
Evaporator entering and leaving fluid
temperatures
Condenser water entering and
leaving water temperature
Current limit setpoint
Evaporator flow and condenser flow
(optional)
Outdoor temperature (optional)
Fluid or water pressure drops
(optional) evaporator and condenser
Active ice-making setpoint (if
applicable)
Active hot water setpoint (if
applicable)
Auxiliary heat recovery temperature
(if applicable)
Refrigerant Report
Refrigerant Temperatures and
Pressures
ppm of refrigerant from multiple
points outside of machine
Saturated condenser temperature
Condenser pressure
Saturated evaporator temperature
Evaporator pressure
Compressor discharge temperature
(optional)
Purge suction temperature
Purge elapsed time
Pumpout activity
Compressor Report
Starts and hours counters
Phase currents
Phase voltages (optional)
Oil temperature and flow
Motor winding temperature
Bearing temperatures (optional)
Kilowatts/power factor (optional)
Controls
Functions/
Diagnostics
Diagnostics
Water and refrigerant temperatures out
of range
Loss of flows
Sensor and switch faults
Overload trips
Over/under voltage (if applicable)
Surge/extended surge
Compressor acceleration failure
Transition failure
Other drives faults
Distribution faults
Oil pressures and temperatures out of
range
High condenser pressure cutout
Low and high differential pressure
Emergency stop
Loss of communications to other
sources
Microprocessor memory errors
High motor winding temperature
Excessive purge activity
Operator Interface
The Trane CenTraVac chiller control
panel, UCP2 is easy to use, understand,
to access information, to read, to change
setpoints, to diagnose problems, to
maintain, and to reset after shutdown.
Convenience
Enunciation of all information is at the
front panel display (including power,
voltage, amps, purge, pressures,
refrigerant monitoring, and number of
starts data)
Messages displayed using clear
language
Readability
LCD multi-language display that is
easy to read from a distance anywhere
within a 60 degree angle.
LCD backlight so that the display can
be read in a variety of equipment room
lighting.
Customizable reports with
understandable messages.
Maintainability and Serviceability
Keypad programmability no
setpoint potentiometers
No batteries configuration stored in
nonvolatile memory
Logically arranged report groups with
report header and setpoint groups
Selectable security
Variable points updated every two
seconds
Messages that direct user to problem
source via a menu item
Application Flexibility
Eight languages available
Metric (SI) units or English
Remote display interface (optional)
For more information on the Trane
centrifugal chiller unit control panel,
please contact your local Trane sales
engineer.