AKG Acoustics C 411 Microphone User Manual


 
21
6 Specifications
Type: pre-polarized condenser transducer
Polar pattern: figure 8
Frequency range: 10 Hz to 18,000 Hz
Sensitivity at 1 kHz: 1 mV/ms
-2
(vibration pickup)
Impedance: 200 , unbalanced
Recommended load impedance: 1000
Max. SPL for 1%/3% THD: 96 / 103 dB SPL
Power requirement:
C 411
III
PP: 9 to 52 V universal phantom power
C 411
III
L: B 29 L battery power supply,
MPA III L phantom adapter,
AKG WMS bodypack transmitters
Current consumption: approx. 2.2 mA
Cable length/Connector: C 411
III
PP: 3 m (10 ft.) / 3-pin male XLR
C 411
III
L: 1.5 m (5 ft.) / 3-pin mini XLR
Finish: matte black
Size: 27 x 14 x 9.5 mm (1 x 0.6 x 0.4 in.)
Net/shipping weight: C 411
III
PP: 98 g (3.5 oz.) / 225 g (8 oz.)
C 411
III
L: 18 g (0.6 oz.) / 150 g (5.3 oz.)
This product conforms to EN 50 082-1 provided it is connected to equipment
with a CE mark.
Frequency Response Polar Diagram
Cleaning: To clean the pickup case, use a soft cloth moistened with
water.