Behringer B315A DJ Equipment User Manual


 
ENGLISH
EUROLIVE B312A/B315A User Manual
4
The
[3]
LINK OUTPUT is directly connected to the inputs
of the B312A/B315A and carries the input signal with no
processing applied. In this way, you can route the signal
to the input of another device (for example, a second
B312A/B315A)
To set the volume of the LINE or MIC signal, use the
[4]
LEVEL control. The left half of the control range is for
attenuating the LINE signal. The right half is for raising
the level of the MIC signal.
The
[5]
CLIP LED lights up when signal distortion occurs.
Reduce the volume with the LEVEL control until the CLIP
LED does not light up any more, or occasionally lights up at
signal peaks.
We would like to draw your attention to the fact that
extremely loud sound levels may damage your hearing as
well as your headphones/loudspeakers. Turn the LEVEL
control fully to the left before you switch on the unit.
Be careful to select a suitable volume at all times.
The
[6]
HIGH control adjusts the high-frequency range.
Use the
[7]
LOW control to raise the level of the low-frequency
range.
The
[8]
PWR LED lights up when the loudspeaker is put into
operation.
You can replace fuses at the
[9]
FUSE SWITCH of the
B312A/B315A. Always replace fuses with the same type.
Please follow the instructions given in the chapter
“Specications.”
The mains connection is established using a cable with
[10]
an IEC mains connector. This cable is delivered with the
B312A/B315A. To avoid ground-loop hum, loudspeakers
and mixing consoles should be connected to the same power
circuit.
Press
[11]
POWER to turn on your B312A/B315A.
The POWER switch does not fully disconnect the unit from
the mains. To disconnect the unit from the mains, pull out
the main cable plug or appliance coupler. When installing
the product, ensure the plug or appliance coupler is readily
operable. Unplug the power cord completely when the unit
is not used for prolonged periods of time.
Serial number
[12]
Fig.2.2: Control elements and connections B312A and B315A)