Behringer PMP5000 DJ Equipment User Manual


 
12 EUROPOWER PMP1000/PMP3000/PMP5000 User Manual
Wiring Examples5.
Loudspeaker connection (monitor mix)
Loudspeaker connection (monitor mix)
PMP1000/PMP3000/
PMP5000 (part view)
2 x BEHRINGER EUROLIVE
Stack (B1500 & B1020, both passive)
front panel (part view)
Footswitch
Link output
2 x BEHRINGER B300 (active)
Fig. 5.1: Stereo operation
For stereo operation the POWER AMP switch (27) must be set to its upper position
(MAIN or MAIN L/MAIN R). Outputs A and B provide the stereo main signal for
passive speakers. The preamp monitor output is connected to two parallel active
speakers, which are used as on-stage monitors. Use the footswitch to enable/
disable the effects processor.
Subwoofer
PMP1000/PMP3000/
PMP5000 Rear panel
EUROPOWER EP1500
EUROPOWER
B1520
EUROPOWER
B1500X
subwoofer
2 x BEHRINGER B300 (active)
F. O.H. mixMonitor mix
Fig. 5.2: Bridged mono operation
This illustration shows the power mixer with a sub-woofer connected to
OUTPUT B. For a bridged mono operation to OUTPUT B, the AMP MODE selector
switch (27) must be set to its lower position “BRIDGE”. A separate stereo power
amp (BEHRINGER EUROPOWER EP1500) connected to the preamp main outputs
delivers the stereo main signal. Two active monitor speakers for on-stage
operation are connected to the preamp monitor output.