Casio WK-500 Electronic Keyboard User Manual


 
English
Other Useful Digital Keyboard Functions
E-55
You can use the following procedure to select from among 17
preset scales, including the standard Equal Temperament.
1.
Press
bq
.
2.
Press
4
.
3.
Use the
bs
(10-key) [–] and [+] keys to select the
preset scale you want. After selecting a scale,
press the key on the keyboard that you want to
use as the root key (C to B).
There are a total of 17 scales: the 16 shown in the table
above (page E-54) plus Equal Temperament (Number:
00, Scale Name: Equal).
4.
After you are finished, press
4
to assign the
scale to the keyboard.
You can store up to four “user scales” configured by you in
memory for later recall when you need them.
To save a user scale
1.
Press
bq
.
2.
Press
4
.
3.
While holding down
co
, press a button from
ck
to
cn
to select an area.
To recall a user scale
1.
Press
bq
.
2.
Press
4
.
3.
Use buttons
ck
to
cn
to select the user scale
you want to recall.
Saving Data on an External Device
(WK-500 only)
SD memory card (page E-61)
Computer (page E-68)
Maintaining Data in User Scale Memory
(WK-500 only)
After you save data in user scale memory, it will remain there
as long as power is supplied to the keyboard. However, if you
disconnect the AC adaptor when there are no batteries
loaded, data in user scale memory will be deleted.
Tips for Maintaining Data
Use both batteries and the AC adaptor together.
Make sure that batteries with sufficient power are loaded
whenever you disconnect the AC adaptor.
Connect the AC adaptor to the keyboard and plug it into a
power outlet before replacing batteries.
Before connecting or disconnecting the AC adaptor or
replacing batteries, first press
1
to turn off power.
You can use the following procedure to reflect the scale you
adjusted using the scale fine tune or the quarter tone function,
or the preset scale you selected with the preset function in
Auto Accompaniments.
1.
Press
ct
and then use the
bs
(10-key) [4] ( )
and [6] ( ) keys to display “OTHER” (page
E-6).
2.
Press
bs
(10-key) [7] (ENTER) key.
3.
Use the
bs
(10-key) [4] ( ) and [6] ( ) keys
to display “AcompScl”.
4.
Use the
bs
(10-key) [+] key to select on.
Recalling a Preset Scale (WK-200 Only)
Saving User Scales (WK-500 Only)
E
q
u a l
Scale Name
Using the Current Scale Notes for Auto
Accompaniments
OTHER
Flashes
WK200_e.book 55 ページ 2008年5月16日 金曜日 午後8時44分