DIAGNOSTIC STATUS CODES
SX TRANSISTOR CONTROL Page 37
January 2000
TRACTION
STATUS CODE
DESCRIPTION OF STATUS CAUSE OF STATUS INDICATION
-67
The armature current exceeds the
armature transistor limit.
This status code will be displayed when the armature
transistor exceeds its specific current limit. The
control is reset by recycling the key switch.
MEMORY RECALL
YES
CORRECTIVE ACTIONS TROUBLE-SHOOTING DIAGRAM
Circuits valid
for
Traction
Controller
SYMPTOM
Control will not operate.
POSSIBLE CAUSE
•= Shorted motor armature A1 to A2
•= Power cables may be shorted to each other
(Measure at control terminals)
•= A1 to A2 terminals may be shorted to battery
positive or negative
KEY SWITCH
L
P7
P1
P17
P2
P6
P9
P3
P12 P8
P4
P5
SEAT SW.
START SW.
FOR. SW.
REV.
SW.
P10
P18
PY7
PY12
PY10
PY11
SP
P1
P5
P4
P2
F
U
7
TO
ACCESSORIES
FU6
P3
OSCILLATOR CARD
LEFT CONTROL
FU1
STEER
ANGLE
POT
LINE
POWER
CONNECTIONS
LEFT CONTROL
POS
A1 F1
NEG A2
F2
FIELD
ARMATURE
ACC POT
BDI INTERRUPT
+
-
SP
SP
FU4
A1
FU2
P
P
POWER
CONNECTIONS
RIGHT CONTROL
POS A1 F1
NEG
F2
FIELD
ARMATURE
FU5
BRAKE SW.
A2