Nortel Networks VSN04 Recording Equipment User Manual


 
38 Common TOPS VSN log messages (0202)
TOPS VSN Log and alarm messages
0003/010E
Message:
[PRU_name] received an IO error (PERM_Denied) on path
[file/directory_path name]. The error was the result of permission denied.
Description:
The PRU encountered an error during an IO operation on the
file or directory. The operation was not performed. It is the responsibility of the
PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If this action doesn't correct the
problem, reboot the SRU. If the PRU is still faulty, then reboot the whole
system. Document the problem, record all action taken, and then contact NT.
0003/0129
Message:
[PRU_name] received an IO error (Special_File) on path
[file/directory_path name]. The error was the result of a SFS special file for
UNIX.
Description:
The PRU encountered an error during an IO operation on the
file or directory. The operation was not performed. It is the responsibility of the
PRU performing the operation to recover from the error and to retry the
operation. If it is unable to do so, then it can declare itself faulty.
Action:
If the PRU is in the working state, no action is required. If the PRU is
in the faulty state, then reboot the PRU. If the problem persists, then reboot
the server which handles the IO operation. If this action doesn't correct the
problem, then reboot the SRU. If the PRU is still faulty, then reboot the whole
system. Document the problem, record all action taken, and then contact NT.