ACPE Resource Manager Log Messages (9440) 55
TOPS VSN Log and alarm messages
0000/0028
Message:
<PRU_name> (Tokenizer) Disk status is now lower than threshold.
Will start collection.
Description:
Sample data collected is now written to disk. The daily audit
has made room for new sample data. Call processing continues as usual and
no effect to service is seen.
Action:
No action.
0000/002A
Message:
<PRU_name> Tokenizer logged into server. Collection will start.
Server name = <server_id>.
Description:
Sample data is collected via server. Call processing continues
as usual and no effect to service is seen.
Action:
No action.
0000/002B
Message:
<PRU_name> Tokenizer located file server. Collection will start.
Server name = <server_id>.
Description:
File server has been located. File server is required for the
collection of sample data. Call processing continues as usual and no effect to
service is seen.
Action:
No action.
0001/0004
Message:
[PRU_name] could not query the ACPE [queried_PRU_name], for
its loading. The length of data returned did not match the length requested.
Description:
There has been a data mismatch between the ACPE-RM and
the ACPE. This mismatch is probably the result of incompatible PRU versions.
Action:
Both the ACPE-RM and the ACPE should be reloaded from tape,
and then brought back into service. Keep a record of the error for NT.
0001/0005
Message:
[PRU_name] could not query the ACPE [queried_PRU_name], for
its calls. The length of data returned did not match the length requested.
Description:
There has been a data mismatch between the ACPE-RM and
the ACPE. This mismatch is probably the result of incompatible PRU versions.
Action:
Both the ACPE-RM and the ACPE should be reloaded from tape,
and then brought back into service. Keep a record of the error for NT.
0001/0006
Message:
[PRU_name] has filled up it's table for handling ACPEs.
[PRU_name_2] will not be added. The maximum number of supported ACPEs
is <number>.
Description:
A maximum number of ACPEs are supported. The maximum
number has been reached and all others brought into service are ignored.
Action:
No action.
0001/0007
Message:
[PRU_name] has filled up it's table for handling calls. The maximum
number of supported calls is <number>.
Description:
A maximum number of calls are supported. The maximum
number has been reached and all others presented to the PRU are ignored.
Action:
No action.
0001/0020
Message:
[PRU_name] could not get a heap for the tokenizer task. No token
could be issued. [Two 80 character lines of optional data.]
Description:
Unable to issue tokens. Call processing continues as usual
and no effect to service is seen.