RECOMMENDED WIRING DISTANCES
Refer to Table C for the recommended maximum distances (transformer to load), which are calculated with a 10 percent voltage drop. Distances
are calculated in feet; values in parentheses are in meters.
POWER CONSUMPTION
Table D contains the estimated power consumption information for each model. These calculations are based on an input frequency setting of
60 Hz for 115 VAC and 50 Hz for 230 VAC.
Table C. Recommended Wiring Distances
Voltage
Total VA
Consumed
Wire Gauge
20 AWG (0.5 mm
2
) 18 AWG (1.0 mm
2
) 16 AWG (1.5 mm
2
)
26 Volts
10 333 ft (101 m) 529 ft (161 m) 840 ft (256 m)
20 166 ft (50 m) 264 ft (80 m) 420 ft (128 m)
30 111 ft (33 m) 176 ft (53 m) 280 ft (85 m)
50 66 ft (20 m) 105 ft (32 m) 168 ft (51 m)
Table D. Estimated Power Consumption
Model Input Voltage Input Fuse Maximum Load BTU/H*
RCS8B5/
RCS8F5
115 VAC 1.6 A 143 W, 1.24 A 72
230 VAC 1 A 143 W, 0.62 A 72
RCS16B10/
RCS16F10
115 VAC 3 A 280 W, 2.44 A 123
230 VAC 1.6 A 282 W, 1.22 A 119
RCS16B20/
RCS16F20
115 VAC 5 A 549 W, 4.27 A 313
230 VAC 3 A 542 W, 2.35 A 198
RCS32B20/
RCS32F20
115 VAC 5 A 549 W, 4.27 A 313
230 VAC 3 A 542 W, 2.35 A 198
*BTU/H values for the transformer are equal to the difference between input
power and output power.