2
MIDI Implementation
l
Pitch Bend Change
Status 2nd byte 3rd byte
EnH llH mmH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = Pitch Bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
n
Channel Mode Messages
l
All Sounds O (Controller number 120)
Status 2nd byte 3rd byte
BnH 78H 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* When this message is received, all notes currently sounding on the corresponding
channel will be turned o.
l
Reset All Controllers (Controller number 121)
Status 2nd byte 3rd byte
BnH 79H 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* When this message is received, the following controllers will be set to their reset
values.
Controller Reset value
Pitch Bend Change +/-0 (center)
Modulation 0 (o)
Expression 127 (max)
Hold 1 0 (o)
l
All Notes O (Controller number 123)
Status 2nd byte 3rd byte
BnH 7BH 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* When All Notes O is received, all notes on the corresponding channel will be turned
o. However, if Hold 1 is ON, the sound will be continued until these are turned o.
l
OMNI OFF (Controller number 124)
Status 2nd byte 3rd byte
BnH 7CH 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes O is received.
l
OMNI ON (Controller number 125)
Status 2nd byte 3rd byte
BnH 7DH 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes O is received. OMNI ON
will not be turned on.
l
MONO (Controller number 126)
Status 2nd byte 3rd byte
BnH 7EH mmH
n = MIDI channel number: 0H - FH (ch.1 - 16)
mm = mono number: 00H - 10H (0 - 16)
* The same processing will be carried out as when All Notes O is received. MONO will
not be turned on.
l
POLY (Controller number 127)
Status 2nd byte 3rd byte
BnH 7FH 00H
n = MIDI channel number: 0H - FH (ch.1 - 16)
* The same processing will be carried out as when All Notes O is received. MONO will
not be turned o.
n
System Realtime Message
l
Timing Clock
Status
F8H
* This is received when the CLOCK SOURCE parameter (System Parameter) is MIDI or
USB.