Sanyo MPX-MD4 Musical Instrument User Manual


 
SPECIFICATIONS
Signal format : Based on NTSC color signal standard (MPX-CD4)
Based on NTSC B/W signal standard (MPX-MD4)
Camera signal input synchronization : Asynchronous
Camera input terminals (IN) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 4
Camera output terminals (OUT) : Throughput of each input, 1.0 Vp-p/75 , BNC connector x 4
VCR input terminal (VCR IN)
Composite input : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
S-VHS input terminal (S-VHS VCR IN) : Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,
unbalanced
VCR output terminal (VCR OUT)
Composite output : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
S-VHS output terminal (S-VHS VCR
OUT)
: Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,
unbalanced
Monitor 1 output terminal (MONITOR OUT 1) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
Separate YC signals, DIN connector (S terminal) x 1 (MPX-CD4 only)
Y signal: 1.0 Vp-p/75 , unbalanced, synchronous; C signal: 0.286 Vp-p/75 ,
unbalanced
Camera live picture or VCR playback picture signal output: full screen, sequential
display, 4 divisions split screen
Monitor 2 output terminal (MONITOR OUT 2) : VS/VBS, 1.0 Vp-p/75 , BNC connector x 1
Camera live picture signal output: full screen (can be set in (MONITOR SET) menu
to display the same image as monitor 1)
Control terminal (CONTROL)
Alarm input (1 4) : No voltage, make-contact switch input x 4 (Low input)
Remote input (R1, R2) : 2-wire type with resistance-based identification system
Alarm output (A) : DC 5 V, 5.7 k (Low output)
Switching input (S) : Low input, for input signal from SW OUT of timelapse VCR/real time recorder (as
per this manufacturer specifications)
RS-232C terminal : 9-pin D-SUB
Full screen sequence timing : Available in full screen, 8 settings (1, 2, 3, 4, 5, 10, 20, 30 sec.)
Monitor on-screen display : Title (up to 10 characters), date, time selectable
Menu settings : 9 menus: Language, Clock, Title, Alarm, Sensor, Timer, Display, VCR, Alarm data
Alarm sensor : Internal, 4 channel (each camera input, selectable)
Back-up function : Back-up for up to 30 days of the clock settings after connected for 30 hours
continuously
Operations
Still : Available for camera live or VCR playback in 4 divisions split screen, full screen and
zoomed in picture
Can be set using a menu to operate automatically when there is an alarm trigger
Zoom : Available for camera live or VCR playback in 4 divisions split screen, full screen and
frozen picture
In full screen mode can switch from frozen to zoomed in picture
Power : AC 120 V, 60 Hz
Consumption : 19 W (MPX-CD4), 14 W (MPX-MD4)
Operating environment : Temperature: 5 to 40˚C, Humidity: 10 to 80%
Dimensions : 420 (W) x 44 (H) x 325 (D) mm
Weight : Approx. 3.4 kg
Products are subject to change in design and specifications without notice and without incurring any obligation.
L8FH5/US (MPX-CD4 GB) 1999. 6. 4
English 39