Shure microphone mixer DJ Equipment User Manual


 
6
NOTE: When interconnecting the FP24 and FP33, inputs from
the FP24 appear at the FP33 mixbus with their polarity reversed.
(This is unavoidable due to the nature of the interconnection.) To
avoid cancellation or interference effects (e.g., comb filtering) be-
tween the signals from the FP24 and FP33 inputs, use Shure
A15PRS polarity inverters on the FP24 inputs, or do one of the fol-
lowing:
Keep microphones connected to the FP24 as far away as
possible from those connected to the FP33.
For microphones that must be close together (such as those
in a stereo pair), connect them to the same mixer.
NOTE: If constructing your own FP24/FP33 interconnect cable:
Keep cable length to a minimum, since the interconnection
is unbalanced.
Be sure to drive the FP33 mix bus off of pin 2 of the FP24
since the FP24 inputs are reverse polarity with respect to
FP33 inputs.
FP24 XLR–L
FP24 XLR–R
820 ohm
820 ohm
FP33 mixbus
Figure 4. FP24/FP33 Mix Bus Interconnect Cable
Positive: Solder to center pin
(marked with a white stripe on PS20 cable)
Negative: Solder to sleeve
Figure 5. Attaching the Supplied Threaded Power
Connector.
Certification
Authorized under the DECLARATION OF CONFORMITY provision of FCC part 15
as a Class B digital device. Tested to comply with FCC standards. FOR HOME OR
OFFICE USE. This product complies with part 15 of the FCC rules. Operation is
subject to the following two conditions: (1) this device may not cause harmful
interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. Changes or modifications not
expressly approved by Shure Incorporated could void your authority to operate this
equipment.
This equipment has been tested and found to comply with the limits for a class B
digital device, pursuant to Part 15 of the FCC rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the
following measures:
S Reorient or relocate the receiving antenna
S Increase the separation between the equipment and the receiver
S Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected
S Consult the dealer or an experienced radio/TV technician for help
This class B digital apparatus complies with Canadian ICES–003.
Eligible to bear CE marking.
Conforms to European EMC directive 89/336/EEC: Professional Audio Products
Standard EN 55103 (1996); Part 1 (emissions) and Part 2 (immunity). The FP24 is
intended for use in environments E1 (residential) and E2 (light industrial) as defined in
European EMC standard EN 55103. It meets the applicable tests and performance
criteria found in the standard for these environments. EMC conformance is based on
the use of shielded interconnecting cables.
N 108
Limited Two-year Warranty
Shure Incorporated (“Shure”) hereby warrants that this product will be free from de-
fects in materials and workmanship for a period of two years from date of purchase.
At its option Shure will repair or replace the defective product and promptly return it to
you, or refund the purchase price. You should retain proof of purchase to validate the
purchase date and return it with any warranty claim.
If you believe this product is defective within the warranty period, carefully repack
the unit, insure it, and return it postage prepaid to:
Shure Incorporated
Attention: Service Department
5800 W. Touhy Avenue
Evanston, Illinois 60714–4608 U.S.A.
Outside the United States, return the product to your dealer or Authorized Service
Center.
This warranty does not apply in cases of abuse or misuse of the product, use con-
trary to Shure’s instruction, or unauthorized repair. All implied WARRANTIES OF MER-
CHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE are hereby disclaimed
and Shure hereby disclaims liability for incidental, special, or consequential damages
resulting from the use or unavailability of this product.
Some states do not allow limitations on how long an implied warranty lasts, or the
exclusion or limitation of incidental or consequential damages, so the above limitation
may not apply to you. This warranty gives you specific legal rights, and you may have
other rights which vary from state to state.
FCC Declaration of Conformity
We of
Shure Incorporated
5800 W. Touhy Avenue
Evanston IL 607144608 U.S.A.
847–600–2000
declare under our sole responsibility that the following product,
Model: FP24 Name: FP24 Microphone mixer/preamplifier
was tested and found to comply with Part 15 of the FCC rules.
Operation is subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference received, includ-
ing interference that may cause undesired operation.
Testing was completed by the following NVLAP or A2LA accredited laboratory:
L.S. Compliance, Inc.
W66 N220 Commerce Court
Cedarburg, Wisconsin 53012
Telephone 262–375–4400
Fax 262–375–4248
Shure Incorporated, Manufacturer.
Signed:
Date: Sept. 15, 2000
Name, Title: Craig Kozokar, Project Engineer, EMC
SHURE Incorporated Web Address: http://www.shure.com
5800 W. Touhy Avenue, Niles, IL 60714-4608, U.S.A.
In U.S.A., Phone: 1-847-600-2000 Fax: 1-847-600-1212
In Europe, Phone: 49-7131-72140 Fax: 49-7131-721414
In Asia, Phone: 1-852-2893-4290 Fax: 1-852-2893-4055
International Fax: 1-847-600-6446