Shure scm810 Microphone User Manual


 
16
Asia, Pacific:
Shure Asia Limited
22/F, 625 King’s Road
North Point, Island East
Hong Kong
Phone: +852-2893-4290
Fax: +852-2893-4055
Email: info@shure.com.hk
www.shureasia.com
United States, Canada,
Latin America, Caribbean:
Shure Incorporated
5800 West Touhy Avenue
Niles, IL 60714-4608 USA
Phone: +1 847-600-2000
Fax: +1 847-600-1212 (USA)
Fax: +1 847-600-6446
Email: info@shure.com
www.shure.com
©201 Shure Incorporated
Europe, Middle East, Africa:
Shure Europe GmbH
Jakob-Dieffenbacher-Str. 12,
75031 Eppingen, Germany
Phone: +49-7262-92490
Fax: +49-7262-9249114
Email: info@shure.de
www.shure.eu
Change Off-Attenuation Level
This modification changes the off-attenuation level from -15 dB to a
selected value. Select from the following resistor values.
Procedure:
Remove resistors R9088 and R9145. Install new resistor
at jumper points
X904 and X908.
Increase Hold Time
In addition to the dip switch SW702 options of 0.4- and 1.0-second hold
time, the hold time can be increased to 1.5 seconds. (More than 1.5
seconds is not recommended.)
Procedure:
Install a 470 k resistor across jumper points X902. Move DIP switch down
to 1.0-second position.
Decrease Hold Time
The hold time can be decreased from the factory preset of 0.4 seconds to
0.3 seconds. (Less than 0.3 seconds is not recommended.)
Procedure:
Install a 2 M resistor at jumpers X903.
Remote Control of Link Global/Local, Off-Attenuation, Last Mic Lock-on,
and Automatic/Manual DIP Switches
If desired, these functions can each be remotely controlled with an SPST
switch.
Procedure:
1. Solder a wire in the pc board jumper hole adjacent to the desired
function (printed on the printed circuit board). These jumpers are
located just behind DIP switch SW902.
2. Solder a wire in the pc board jumper hole marked “GND” near switch
SW902.
3. Set the desired DIP switch(es) to the Up position.
4. Run the jumper wires to the desired remote location and solder them
to an SPST toggle switch. The wires can exit the SCM810 chassis
above the DIP switches. Shorting any wire to the Ground wire will set
the function(s) to the corresponding switch “down” position.
Off-Attenuation Level Resistor Value
10 dB 18 k
20 dB 50 k
30 dB 150 k