SX-ST / SX-SV User Manual page 9
2.2.3 Closing the battery compartment
Replace the plastic side cover and tighten the screw. ( Do not over tighten )
NOTE: Certain D-Cells are longer than standard D-Cell batteries and slight difficulty may be found in
closing the compartment if such batteries are used. Your nearest SONOSAX agent or the
manufacturer in Switzerland can provide assistance if a problem arise due to this difference
in length.
Replace the battery compartment while holding in the slide-locks and make sure the power contacts are
correctly positioned. The battery compartment is in place when the slide-locks return easily to their original
position.
2.2.4 Batteries charger (option for SX-ST Series only)
An external NiCd or NiMH batteries charger is available for the SX-ST Series. (part nr SX 008415 )
You do not need to remove the cells from the battery tray to individually recharge the batteries.
A connector located at the right side of the battery tray is provided to recharge all 12 cells at once. Simply
remove the battery compartment as described at section 2.2.1 and connect appropriate charger to the battery
pack.
WARNINGS:
- Never attempt to charge alkaline D-Cell batteries ( high risk of explosion ! )
- Charger must be suitable for 14,4 V batteries
- Make sure that your NiCd or NiMh batteries accept high current charge when using a fast charger
2.3 External DC Power Mode (SX-ST Series only)
The SONOSAX SX-ST mixer can be powered from an external 10,5 to 18 Volts regulated DC power supply,
capable of delivering at least 2.5A. The average power consumption is approximately 2A.
The SX-ST series is supplied with an auto-ranging power supply 100 to 240 VAC 50 or 60 Hertz, that can be
used worldwide without modification or setting changes.
The DC power supply input connector (XLR 4 pin, SONOSAX Part Number xxxxxxxx) is located on the rear
panel of the SX-ST mixer. Pin 1 is 0V or negative / Pin 4 is positive +10,5 to +18VDC