Yamaha 01V96 Musical Instrument User Manual


 
Transmitting Parameter Settings via MIDI (Bulk Dump) 227
01V96 Version 2—Owner’s Manual
MIDI
18
The following options are available:
ALL.................................This button selects all data available for bulk dump. When this
button is turned on, all other buttons in this section are turned
off.
SCENEMEM .................This button selects Scene memories. You can select Scenes you
wish to transmit in the parameter box next to the button.
LIBRARY.......................This button selects libraries. You can select the type of library in
the TYPE parameter box (next to the button), then specify the
library number in the parameter box on the right.
BANK.............................This parameter enables you to select the User Defined Key
banks (KEYS UDEF), User Defined Remote Layer banks (RMT
UDEF), or User Assignable Layer banks (USR LAYER) for bulk
dump. You can select one of these three types in the parameter
box next to the button, and select the banks in the parameter
box on the right.
SETUPMEM .................This button selects the 01V96 setup data (i.e., system settings).
PGM TABLE .................This button selects the MIDI | Pgm Asgn page settings.
CTL TABLE...................This button selects the MIDI | Ctl Asgn page settings.
PLUG-IN .......................This button selects the settings of an optional Y56K card
installed in the slot. You can select Y56K card programs in the
parameter box next to the button..
5 If necessary, move the cursor to the parameter box next to the selected but-
ton, then rotate the Parameter wheel or press the [INC]/[DEC] buttons to
select the desired bulk dump data.
6To start transmitting bulk data, move the cursor to the TRANSMIT button,
then press [ENTER].
Bulk Dump is executed. During the operation, the Bulk Dump window appears, indicating
the current bulk dump status. To abort the bulk dump operation, move the cursor to the
CANCEL button in the window, then press [ENTER].
7To receive bulk data, press the DISPLAY ACCESS [MIDI] button again to dis-
play the MIDI | Setup page, then turn on the Rx ON/OFF button in the BULK
row.
Now, when the 01V96 receives bulk data, the corresponding internal data is updated.
Note: Data selected by the SETUPMEM button includes MIDI transmission and reception
port settings and message settings. After you store to an external device bulk dump data that
has its reception disabled, if the 01V96 later starts to receive this particular data, 01V96 bulk
dump reception will be turned off immediately, and the 01V96 will be unable to receive sub-
sequent data. Therefore, before you store the data selected by the SETUPMEM button using
Bulk Dump, be sure to enable bulk data transmission and reception.
Tip: If you selected [ALL] in the parameter box, all data selected by the corresponding button
is transmitted as bulk dump data.
Tip: To transmit bulk dump request messages, move the cursor to the REQUEST button, then
press [ENTER]. If you set up the 01V96 so that it will transmit and receive MIDI messages to
and from another 01V96, the other 01V96 will respond to the bulk dump request and transmit
the bulk dump data to the 01V96 you are operating.