Yamaha 01V96 Musical Instrument User Manual


 
98 Chapter 8—Bus Outs
01V96 Version 2—Owner’s Manual
METER
This section enables you to switch the metering position of signal levels that are displayed
on the Meter page or by the stereo meter to the right of the screen. (See page 34 for more
information on selecting the metering position.)
Bus Out 1–8
The Bus Out 1–8 section mixes signals routed from Input Channels to the specified buses,
processes them using on-board EQ, compressor, etc., then routes them to the specified out-
put connectors or I/O card.
The following diagram illustrates the Bus Out signal flow.
INSERT
•ATT (Attenuator)
•4 BAND EQ (4-band equalizer)
COMP (Compressor)
ON (On/Off)
LEVEL
OUTPUT DELAY (Output delay)
METER
The parameters and sections listed above are identical to those for the Stereo Out. For more
information, refer to the explanation of the Stereo Out (see page 97).
Bus to Stereo
Bus Out 1–8 signals are also routed to the Stereo Bus. In addition to the ON, LEVEL, and
other parameters, you can also set the Send Level, On/Off, Pan, and other parameters.
Note: You can also patch the Stereo Out signals to other output connectors or the I/O card by
using the Patch | Out Patch pages.
Tip:
•You can also pair adjacent odd-even buses for stereo operation (see page 105).
•By default, Slot channels 1–8 and 9–16 and ADAT OUT channels 1–8 are patched to the
Bus Out 1–8 outputs. However, you can change this patching on the Patch | Out Patch page
(see page 123).
OUTPUT PATCH
OUTPUT
DELAY
METER
ATT
4BAND
EQ
INSERT
INSERT
LEVEL
ON
COMP
METER
(Gain Reduction)
INSERT
METER
METER
(Out Meter)
STEREO L
STEREO R
BUS1
BUS2
BUS3
BUS4
BUS5
BUS6
BUS7
BUS8
PA N
BUS to STEREO
LEVEL
ON
BUS 1(...8)