General Specifications
Output impedance of signal generator: 150 ohms
*
These specifications apply to rated power supplies of 120V, 230V and 240V
.
MIN
TYP MAX UNIT
Maximum Output Power
(SPEAKERS)
(RL=4 ohms) Both ch drive, 1kHz, THD+N 0.5% 500
W
(RL=8 ohms) 350
(US,AU)
320
(EU)
Total Harmonic Distortion
(THD+N) 20 Hz-20 kHz
(ST, ST SUB, AUX, EFFECT) +14dBu output into 600 ohms 0.3 %
(REC) 0 dBV output into 10 kohms 0.5 %
Frequency Response (ST, ST SUB, AUX, EFFECT)
GAIN at minimum level, PAD=OFF, 20Hz-20kHz,
nominal output level @ 1kHz
–3.0 0.0 1.0 dB
(SPEAKERS) –3.0 0.0 1.0 dB
EIN=Equivalent Input Noise (ST OUT) GAIN at maximum level, 20Hz-20kHz –128 dBu
Residual Output Noise (SPEAKERS) –68 dBu
(ST, ST SUB, AUX) –95 dBu
Crosstalk @ 1kHz adjacent inputs –68 dB
input to output –68 dB
Maximum Voltage Gain
@1kHz
CH MIC INPUT
SPEAKERS 109 dB
CH MIC INPUT
ST OUT 84 dB
CH MIC INPUT
AUX SEND (PRE), ST SUB 80 dB
CH MIC INPUT
AUX SEND (POST) 90 dB
CH MIC INPUT
EFFECT SEND 78 dB
CH MIC INPUT
REC OUT 62.2 dB
ST CH 11/12,13/14
ST OUT 58 dB
Phantom Voltage (CHs 1-6, 7/8, 9/10) No load 48 V DC
Monaural/Stereo channel
Equalizer
± 15 dB (Maximum Variation)
Tu rn over/roll-off frequency of shelv-
ing, 3 dB below maximum variable
level.
HIGH 10kHz (shelving)
MID (MONO) 250-5kHz (peaking)
MID (ST) 2.5kHz (peaking)
LOW 100Hz (shelving)
PEAK Indicator On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) comes within 3 dB of the clipping level.
SIGNAL Indicator On each channel: indicator lights if post-EQ signal (on ST channels, if either
post-EQ signal or post-mic-amp signal) reaches –10 dB.
FCL Indicator Input signal level: –75dB
LEVEL meter (ST, PFL/AFL) Two 12-points LED level meter (PEAK, +5, +3, +1,0, –1, –3, –5, –7, –10, –15,
–20 dB)
PEAK lights if the signal comes within 3 dB of the clipping level.
Graphic Equalizer (ST OUT) 9 band (63, 125, 250, 500, 1k, 2k, 4k, 8k, 16 kHz) ±12 dB (Maximum Variation)
Internal Digital Effect 16 programs, Parameter control
Foot Switch (Internal Effect ON/OFF)
Power Amplifier Protection POWER Switch on/off mute
DC-fault: power supply shutdown/manual reset
Thermal/heatsink temp 90˚C: output mute/auto reset
Vl limiter /RL 2 ohms
Clip limiter/THD 1 % , Indicator
×
2
Power Supply Protection Thermal/heatsink temp 100˚C: power supply shutdown/manual reset
Cooling Dual variable-speed fan
<
=
>
=
<
=
>
=
>
=
MIN
TYP MAX UNIT
Power Consumption 500 W
AC Cord Length 2500 mm
Dimensions Height 155 mm
Depth 493 mm
Width 444 mm
Weight 10.5 kg