![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/d/83/d8370ea7-8b5f-4d88-8642-2657f2247312/d8370ea7-8b5f-4d88-8642-2657f2247312-bg43.png)
Installing and Operating the Module 3 - 11
Make sure that the transmit fiber at one end always connects to a receive
port at the other end.
Caution: Do not connect the 10BASE-FL Module to an ONline
Ethernet Fiber Module, to a 10BASE-FB module, or to
any other module or transceiver that is not
FOIRL-compatibl e or 10BASE-FL-compliant. These illeg al
connections may cause network failure.
Configuring the Module
The ONline management modules can configure the following settings on
the 10BASE-FL Module:
❑ Enable/disable any port on the module
❑ Set the module to a network
❑ Enable redundancy between two ports
❑ Enable remote failure signaling for any port
The following ONline management modules provide network management
capabilities for the ONline System Concentrator and its modules:
❑ Ethernet Management Module V3.20
❑ Token Ring Management Module V3.00
❑ FDDI Management Module V1.01
When an ONline management module is installed in a concentrator, all of
the dip switch settings on the 10BASE-FL Module are overridden.