logo

Installing and Operating the Module 3 - 11
Make sure that the transmit fiber at one end always connects to a receive
port at the other end.
Caution: Do not connect the 10BASE-FL Module to an ONline
Ethernet Fiber Module, to a 10BASE-FB module, or to
any other module or transceiver that is not
FOIRL-compatibl e or 10BASE-FL-compliant. These illeg al
connections may cause network failure.
Configuring the Module
The ONline management modules can configure the following settings on
the 10BASE-FL Module:
Enable/disable any port on the module
Set the module to a network
Enable redundancy between two ports
Enable remote failure signaling for any port
The following ONline management modules provide network management
capabilities for the ONline System Concentrator and its modules:
Ethernet Management Module V3.20
Token Ring Management Module V3.00
FDDI Management Module V1.01
When an ONline management module is installed in a concentrator, all of
the dip switch settings on the 10BASE-FL Module are overridden.