![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/3c/b3c72a76-896a-4f73-b4c6-80a18a4106a7/b3c72a76-896a-4f73-b4c6-80a18a4106a7-bgb5.png)
Serial Connectors and Flex-WAN Cables 181
X.21 DTE Cable
Pinouts
This cable connects the bridge/router to an X.21 DCE.
Figure 35 Flex-WAN and X.21 DTE Connectors
.
Table 29 X.21 DTE Cable Pinouts
Flex-WAN Connector X.21 DTE Connector
Signal Pin Direction Pin Signal Twisted Pair
*
* Unused twisted wires of a twisted pair should be connected to Shield Ground. In this cable this
is one wire of twisted pair 4.
CTS/RTS+ 1 ← 5 Indicate+ 1
CTS/RTS- 2 ← 12 Indicate-
RTS/CTS+ 9 → 3 Control+ 2
RTS/CTS- 10 → 10 Control-
TxD/RxD+ 11 → 2 Transmit+ 3
TxD/RxD- 12 → 9 Transmit-
Circuit Ground 15 - 8 Control GND 4
RxC/TxCE- 25 ← 13 Timing- 5
RxC/TxCE+ 26 ← 6 Timing+
RxD/TxD- 27 ← 11 Receive- 6
RxD/TxD+ 28 ← 4 Receive+
Shield Ground 46 Cable Shield 1 Shield Ground -
Shorting Group 1 47
48
- - - -
Shorting Group 2 51
52
- - - -
60-pin Flex-WAN male connector
To SuperStack II NETBuilder
To DCE
15-pin male connector
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
31 32 33 34 35 36 37 38 39 40 41 42 43 44 45
60 59 58 57 56 55 54 53 52 51 50 49 48 47 46