A SERVICE OF

logo

Security Escort | Technical Reference Manual | 3.0 System Menus
and Screens
EN | 16
Bosch Security Systems | 6/12 | 38947D
Enable Reed Switch
If checked, the reed switch input of
this transmitter is enabled and causes
an alarm. Otherwise, the reed switch
input is disabled. The alarm group this
transmitter is assigned to must be
armed, for this input to cause an
alarm, which is displayed. If no alarm
group is assigned, the transmitter is
always armed. To enable this option,
the transmitter’s class must be set to
point type.
Optional Text
This is optional text that can be added
to the location text when this input
reports an alarm. To enable this
option, the transmitter’s class must be
set to point type.
Disable Shorted Loop
If selected, a shorted loop on this
transmitter does not cause an alarm or
trouble report to display. To enable
this option, the transmitter’s class
must be set to point type.
Alarm on Shorted Loop
If selected and the alarm group this
transmitter is assigned to is armed, a
shorted loop on this transmitter causes
an Alarm Report to display. For this
input to cause an alarm, the alarm
group this transmitter is assigned to
must be armed, which is displayed. If
no alarm group is assigned, the
transmitter is always armed. To enable
this option, the transmitter’s class
must be set to point type.
Trouble on Shorted Loop
If selected, a shorted loop on this
transmitter causes a Trouble Report to
display. To enable this option, the
transmitter’s class must be set to
point type.
Alarm When Armed, Trouble When Disarmed
on Shorted Loop
If selected and the alarm group this
transmitter is assigned to is armed, a
shorted loop on this transmitter causes
an Alarm Report to display. If selected
and the alarm group this transmitter is
assigned to is disarmed, then a shorted
loop on this transmitter causes a
Trouble Report to display. If no alarm
group is assigned, the transmitter is
always armed. To enable this option,
the transmitter’s class must be set to
point type.
Disable Open Loop
If selected, an open loop on this
transmitter does not cause an Alarm or
Trouble Report to display. To enable
this option, the transmitter’s class
must be set to point type.
Alarm on Open Loop
If selected and the alarm group this
transmitter is assigned to is armed, an
open loop on this transmitter causes an
Alarm Report to display. The alarm
group this transmitter is assigned to
must be armed for this input to cause
an alarm, which is displayed. If no
alarm group is assigned, the
transmitter is always armed. To enable
this option, the transmitter’s class
must be set to point type.
Trouble on Open Loop
If selected, an open loop on this
transmitter causes a Trouble Report to
display. To enable this option, the
transmitter’s class must be set to
point type.
Alarm When Armed, Trouble When Disarmed
on Open Loop
If selected and the alarm group this
transmitter is assigned to is armed, an
open loop on this transmitter causes an
Alarm Report to display. If selected
and the alarm group this transmitter is
assigned to is disarmed, an open loop
on this transmitter causes a Trouble
Report to display. If no alarm group is
assigned, the transmitter is always
armed. To enable this option, the
transmitter’s class must be set to
point type.
Fixed Location and Pager Text
This is the text that displays as the
location of the alarm for fixed
location transmitters and on pagers
reporting this alarm.
Transponder Name
Select the transponder with the area
that defines the area for a wandering
(virtual fence) alarm. Refer to
Transponder Area for the operation and
setup of the wandering alarm (virtual
fence alarm).