78 en | Configuration Using a Web Browser VideoJet X10
V3.0 | 2007.09 Installation and Operating Manual Bosch Security Systems
Changes to fields followed by the Reboot link are transmitted to the unit by clicking the Set
button; however, they will only be activated once the unit is rebooted.
1. Make the desired changes.
2. Click the Set button.
3. Click a Reboot link to trigger a reboot. VideoJet X10 is rebooted and the changed
settings are activated.
5.28.1 IP address
Enter the desired IP address for the VideoJet X10. The IP address must be valid for the
network.
5.28.2 Subnet mask
Enter the appropriate subnet mask for the selected IP address here.
5.28.3 Gateway address
If you want the unit to establish a connection to a remote location in a different subnet, enter
the IP address of the gateway here. Otherwise leave the box blank (0.0.0.0).
5.28.4 DNS server address
The VideoJet X10 is easier to access if the unit is listed on a DNS server. If you wish, for
example, to establish an Internet connection to the VideoJet X10, it is sufficient to enter the
name given to the unit on the DNS server as a URL in the browser. Enter the DNS server's IP
address. Servers are supported for secure and dynamic DNS.
5.28.5 Video transmission
If the unit is operated behind a firewall, TCP (HTTP Port) should be selected as the transfer
protocol. For use in a local network, select UDP.
5.28.6 HTTP browser port
Select a different HTTP browser port from the list if required. The default HTTP port is 80. If
you want to allow only secure connections via HTTPS, you must deactivate the HTTP port. In
this case, select Off.
!
CAUTION!
If you change the IP address, subnet mask or gateway address, the VideoJet X10 is only
available under the new addresses after the reboot.
!
CAUTION!
Multicast operation is only possible with the UDP protocol. The TCP protocol does not
support multicast connections.
The MTU value in UDP mode is 1,514 bytes.