AN340-EU-EN V1.3 4/13
6
Operation
PowerON‐OFF
1. SwitchthemeterONbypressingthepower buttonmomentarily.
2. PressagaintoswitchthemeterOFF.
3. IfthemeterdoesnotswitchON,checkthatthemeterhassix(6)freshAAAbatteries
installedintherearbatterycompartment.Refertothebatteryinstallationsectionfor
details.
4. Themetercanalsobepoweredusingthe
9VACpoweradaptor.Thepoweradaptorconnects
tothetopofthemeterusingthejackasshownintheDescriptionsectionofthisguide.
Sleepmode
Themeterwillautomaticallyenterthesleepmode(switchoff)aftertwenty(20)minutesof
inactivity.Todisablethisfeature:withthemeterOFF,pressandholdtheSETandHOLDbuttons
fortwo(2)seconds.TheLCDwilldisplay'n'asitswitchesON.Nowthe sleepmodeisdisabled
andtheusermustpressthepowerbuttonmomentarilytoswitchthemeterOFF.
Measurements
5. ConnectthesensortothejackatthetopofthemeterasshownintheDescriptionsection.
Thensensorandjackarekeyedtoensureproperconnection.Thesensordiameteris18mm
(0.7”)andthetelescopingwandextends1m(39”).
6. WiththemeterswitchedON,usetheMODE
buttontoadvancefromonemeasurementtype
tothenext(airvelocity,airfloworvolume,airtemperature,relativehumidity,wetbulb
temperature,anddewpointtemperature).Notethatforairvolumemeasurementstheuser
mustfirstentertheareavaluefortheductundertestbeforeaccuratereadingscan
bemade.
RefertotheAREAsectionofthisguideforprogrammingdetailsandtotheAppendixfor
additionalinformationonareameasurements,calculations,andunitconversions.
7. Whenmeasuring,airmustenterthevaneonthesideofthesensorwiththeprintedwords
AIRIN.Thesensorwandcan
beextendedusingitstelescopingcapabilityupto1m(39”).
8. Themeasurementisindicatedontheupperdisplaydigitsalongwiththecurrentlyselected
unitofmeasure.Tochangetheunitofmeasure,refertotheSETUPmodesection.Thelower
displaylineshowstherealtimeclock,alternating
timeanddateinformation.
9. Theairtemperatureandrelativehumiditysensorsarelocatedintheslottedopeningonthe
sensorwandbelowtheimpeller.
10. Airvelocityreadingsareindicatedinmeterspersecond(m/s)orfeetperminute(fpm).
Temperaturereadings(air,dewpoint,orwetbulb)areindicatedin°C/°F.RelativeHumidity
isindicatedin%.Airflow(volume)isindicatedinCFM(cubicfeetperminute)orCMM(cubic
metersperminute).
11. Tomeasurerelativehumidityusinganoffsetreferencevalue,pleaseaccesstheSetupmode
andinputtheoffsetvalueasdescribedintheSetupmodesection.TheLCDwilldisplaythe
measuredvalueminustheoffsetvalueoncetheoffsetisprogrammedintheSetupmode.