7
5
CLEARANCE DIMENSIONS
Clearance dimensions (mm)
CG302D
CG451D
CG603D
CG604D
CG752D
CG903D
CG905D
A
minimum clearance from left edge of cutout to nearest combustible surface 120 60 115 130 115 115 130
B
minimum clearance from right edge of cutout to nearest combustible surface 120 60 115 115 115 115 115
C
minimum clearance from rear edge of cutout to:
nearest combustible surface
nearest non-combustible surface
160
45
85
45
160
45
160
45
125
45
125
45
160
45
D
minimum height of non-combustible material when used on adjacent walls 150 150 150 150 150 150 150
E
minimum clearance from glass surface to:
rangehood
any other overhead exhaust fan
downward facing combustible surface
downwards-facing tiled or re resistant surface
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
F
minimum clearance below top of benchtop to:
combustible surface
Fisher & Paykel oven or nearest non-combustible surface
70
65
70
65
70
65
70
65
70
65
70
65
70
65
G
minimum distance from right edge of cooktop to gas connection point on wall
(if using a exible hose)
250 250 250 250 250 250 250
H
distance from oor to gas connection point on wall (if using a exible hose)
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
I
maximum overall depth of overhead cabinetry 600 600 600 600 600 600 600
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the oor and to a distance of at least 250 mm (G) outside the width
of the product, on the right-hand side. It should be accessible with the product installed.
FRONT
ISO
E
H
D
F
G
A
I
B
C