A SERVICE OF

logo

16
Cavity preparation
Cavity
These marks indicate mounting tab screw locations
Note: To align drawer front to adjacent cabinetry, the product to counter top clearance can be
increased to 3 mm.
Preferred position. If adequate clearance, services hole can be higher.
If hole is higher, ensure drain hose(s) are routed straight into the waste connection.
Clamp (1)
Wire clip (1)
Phillips 16 mm
screws (5)
Drain hose
support (1)
Moisture protection tape (1)
(to prevent moisture damage)
Drain hose
joiner (1)
90
o
10 mm
Moisture
protection
tape must
be applied.
max. 450 mm
220-240 VAC
min. 4.5 A
Note: Services can be located
either side of DishDrawer®.
If the Drain hose(s) supplied are not long enough to reach your services, you must use a Drain Hose Extension Kit
P/N 525798 which will extend the drain hose(s) by 3.6m. The kit is available from the nearest Fisher & Paykel
Authorized Service Agent or www.fisherpaykel.com. DO NOT extend beyond this limit.
Important!
Adjacent cabinetry must not
extend above cavity base
min. ø50 mm
SINGLE MODELS
min. 200 mm
*
*
*