2 Cabling Storage Devices and Setting SCSI Addresses
13
English
4. Remove the front bezel. Pull the top of the bezel forward, swinging it
down to clear the retaining clips at the bottom of the chassis. Lift the
bezel away from the chassis, as shown in Figure 2-1.
Figure 2-1. Removing the Bezel and Opening the Door
5. Loosen the door mounting screws using a straight-blade screwdriver.
(The screws remain attached to the door.)
6. Swing the door open, as shown in Figure 2-1.
CAUTION The door is an integral part of the unit. The storage system must
be operated with the door closed to ensure proper airflow for
continued reliability and to maintain compliance with radio
frequency interference (RFI) and safety standards.
7. Lift the door off the chassis (if desired).
Reinstalling the door is accomplished by reversing the procedure.