Installation Checklist
BEFORE LIGHTING THE PILOT:
Check the gaslines for leaks.
a. Use a soapy water solution• DO NOT test for gas leaks .
using a match oropen flame.
b. Brush the soapy water solution on all gaspipes, joints and
fittings.
c. Check,. for bubbling soap. This means you have a leak.
Turn OFF gasandmake the necessary repairs.
d. Recheck for leaks.
e. Rinse off soapy solution and wipe dry.
Is the new temperature-pressure relief valve properly installed
and piped to an adequate drain?See Temperature-Pressure
ReliefValve section.
Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the
"Installation Instructions" section.
Is the water heater completely filled with water? See _Filling"
instructions in the "Installation Instructions"section.
Will a water leak damage anything? See the "Facts to
Consider About the Location"section.
Is there proper dearance between @e water heater and any-
thing that might catch fire? See the Factsto Consider About
the Location section.
Do you have adequate ventilation so that the water heater
will operate properly? See Combustion Air and Ventilation"
in the "Facts to Consider About the Location"section.
s the draft hood vent piping properly secured. See Venung
instructions in the "Installation Instructions" section.
Is there proper clearance between the vent pipe and anythinR
) t . . . . _ v
that m ght catck on fire. See Venting msttuct]ons m the
"Installation Instructions" section.
ls the vent pipe properly sloped and does the vent terminate
outdoors? See "Venting" instructions in the "Installation
Instructions" section.
Do you need to call your gas company to check the gas pipe
and its hookup?
._.-(
HOT
VENT PIPE TO
OUTDOORS
OR CHIMNEY SHUTOFF VALVE
t
_ COLD
UNION
GAS SUPPLY
TEE
DRIP LE(
(Sediment trap)
CApri
DRAFT HOOD 2
TEMPERATURE-
PRESSURE
(Do not cap or plug)
DRAIN VALVE
L
6" AIR GAP
FLOOR DRAIN
MODEL RATING PLATE