![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/0/cb/0cbb6236-88df-4e3b-98ec-933e02e59550/0cbb6236-88df-4e3b-98ec-933e02e59550-bg9.png)
9
INSTALLATION INSTRUCTIONS
3. Insert mounting bolts. Use 3/8 inch x 5 inch wedge
anchors to secure the unit. Place nut and washer on
bolt. Thread nut onto bolt until tops are ush. Strike
bolt with hammer until nut and washer are setting on
top of the compressor foot.
Tighten nut using ratchet with a 9/16 inch socket until
anchor is set (using installation torque specications
of bolt being used). Loosen nut to leave a 1/16 inch
(1.6 mm) gap for stress relief during unit operation.
ELECTRICAL INSTALLATION
Risk of Shock. Improperly
grounded motors are shock
hazards. Make sure all the
equipment is properly grounded.
DANGER WARNING
Risk of Personal Injury or Damage to
Personal Property. Overheating, short
circuiting and re damage will result from
inadequate wiring.
NOTICE
Unit Care and Maintenance. Damage to the
motor from improper electrical voltage or
connection will void the warranty.
WARNING
Risk of Explosion. Disconnect,
tag and lock out power source,
then release all pressure from the
system before attempting to install,
service, relocate or perform any
maintenance.
WARNING
Risk of Shock. All wiring and
electrical connections must be
performed by a qualied electrician
familiar with industrial motor
controls. Installations must be in
accordance with local and national
codes.
GROUNDING
This product must be grounded. Install permanent wiring from the electrical source to the pressure
switch with a ground conductor connected to the grounding screw on the pressure switch. A properly
sized cord with a ground conductor and plug may also be installed by the user.
3
1/16 inch
(1.6 mm)
Concrete
Anchor
Metal
Plate
Rubber
Pad