Calibrate Sensor
Command Structure <ESC>CA
Example: <ESC>CA
Placement: This command should be sent after the sensor type
has been selected with the <ESC>CI command. It
should
not be included with print job commands.
Default: There is no default for this command.
Command Function To adjust the label sensor for unique media and ribbon combinations.
Input to Printer
Printer Output There is no printer output for this command. It will cause the printer to
feed a label while the characteristics of the label backing or eye-mark
are measured.
Special Notes 1. The sensor is calibrated for the currently selected sensor type
(Eye-Mark or Transmissive).
2. If the Sensor is disabled with a <ESC>CI0 command, no
calibration is performed.
3. The sensor must be recalibrated whenever the sensor type is
changed.
4. When calibrating the sensor for the CX200/212TT Thermal
Transfer unit operating in the thermal transfer mode, the ribbon
must be installed in the printer.
Page 90 PN 9001092 Rev. A SATO CX208/212 Printers