Parameter Function / Title Bank Mask Adjustment Range Multiplier
0098
BINARY INPUT STD OR
ADJUSTABLE
0 / 1 0001 0000: Standard (0)
0001: Adjustable (1)
0099
BINARY REF SETTING
POINT #1
0 / 1 00FF
0000 0064 (0 100)
1
009A
BINARY REF POINT
#1 FREQUENCY
0 / 1 FFFF
-Fmax Fmax
0.02
009B
BINARY REF SETTING
POINT #2
0 / 1 00FF
0000 0064 (0 100)
1
009C
1
BINARY REF POINT
#2 FREQUENCY
0 / 1 FFFF
-Fmax Fmax
0.02
009D
JOG RUN FREQUENCY
0 / 1 FFFF
0000 07D0 (0.00 20.00)
0.01
009E
Other
than 0
JOG STOP
METHOD
0 / 1 00C0 0000: Decelerated stop (0)
0040: Coast stop (1)
0080: DC injection stop (2)
009F
PRESET SPEED SELECTION
0 / 1 000F
0000 000F (0 15)
1
00A0
00FF
Reserved
0100
PRESET SPEED
MODE
ACTIVATION
0 / 1 0004 0000: Deactivated (0)
0004: Activated (1)
0101
PRESET SPEED
#1 FREQUENCY
1 FFFF
LL UL
0.01
0102
Other
than 0
PRESET SPEED
#1 OPERATING
MODE
1 040C 0004: (0)
0000: (1)
000C: (2)
0008: (3)
0404: (4)
0400: (5)
040C: (6)
0408: (7)
1
0103
PRESET SPEED
#2 FREQUENCY
1 FFFF
LL UL
0.01
0104
2 or
higher
PRESET SPEED
#2 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
0105
PRESET SPEED
#3 FREQUENCY
1 FFFF
LL UL
0.01
0106
3 or
higher
PRESET SPEED
#3 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
0107
PRESET SPEED
#4 FREQUENCY
1 FFFF
LL UL
0.01
0108
4 or
higher
PRESET SPEED
#4 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
0109
PRESET SPEED
#5 FREQUENCY
1 FFFF
LL UL
0.01
010A
5 or
higher
PRESET SPEED
#5 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
010B
PRESET SPEED
#6 FREQUENCY
1 FFFF
LL UL
0.01
010C
6 or
higher
PRESET SPEED
#6 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
010D
PRESET SPEED
#7 FREQUENCY
1 FFFF
LL UL
0.01
010E
7 or
higher
PRESET SPEED
#7 OPERATING
MODE
1 040C Same as PRESET SPEED #1
OPERATING MODE
1
010F
8 or
PRESET SPEED
#8 FREQUENCY
1 FFFF
LL UL
0.01