8. EPD “Emergency Power Down” Port-Whenanurgentsystemshutdownisrequired,shortthe
two pins together and the sequence portion will be bypassed and turn Off all outputs at the same
time. This EPD feature is commonly used with fire control systems.
9. Delay Pot for Sequence 1 Output - The time between Sequence 1 Output and Sequence 2
Output can be set by rotating the pot following the indicators on the panel. In X1 mode the delay
timeadjustmentisfrom1secondto60seconds.InX10modethedelaytimeadjustmentisfrom
10secondsto600seconds,or10minutes.SeetheFunctionSettingsbelowforSequence1Output
X1 or X10 configuration.
10. Delay Pot for Sequences 2-6 - The time between Sequence 2 Output and Sequence 6 Output can
besetbyrotatingthepotfollowingtheindicatorsonthepanel.Whateverthetimeissettowillbe 
the time between Sequenced outputs.
11. Cable Management Retainer Points - Use the rear panel screws for connecting the included cable
retainers. Each TSD comes with two cable retainers for simplified cable management.
Dip Switch Function Identification
Switch Position
• DIPSW#1-6-ChannelOutputAssignment-EachoutputcanbeassignedtodeliveraHard
Switch Contact Closure (CC) or +24VDC output when activated by the Sequence for Output
Channels 1-6.
• DIPSW#7-LinkAssignmentConguration-Thisswitchdeterminesiftheunitistobea
Master or a Slave unit. The Master unit is always the first in line of the sequence.
• DIPSW#8-SequenceOutput1TimeDelay-IntheX1settingtheadjustabletimedelaysetting
is from 1s to 60s and in the X10 position the time delay setting is from 10s to 600s, or 10 minutes.
Mounting
TherearethreewaystosecurelymountthisTSD:
1. Velcro™ - Each unit includes industrial-grade Velcro™ with adhesive backing to adhere to any
flat surface.
2. Brackets-Eachunitincludestwomountingbracketstosecuretoacabinetorwall.
3. RackMountPanel-TheoptionalTSD-RMKrackmountpanelsupportsuptofourTSDsina
1RU space.
SWITCH FUNCTIONS