Graco 309909H Music Mixer User Manual


 
Technical Data
54 309909H
Technical Data
Mix ratio range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.1:1-10:1 (in 0.1 increments), pump-based systems
0.1:1-30:1 (in 0.1 increments), meter-based systems
Ratio tolerance range . . . . . . . . . . . . . . . . . . . . . . . . . . . . up to +/- 1%
Flow rates
Minimum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.02 qt/min (0.02 lpm)*, pump-based systems
0.1 qt/min (0.1 lpm)*, meter-based systems
Maximum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 gpm (3.8 lpm)
Pump size
UltraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 cc/cycle
HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 cc/cycle
Pump cycle length
(one cycle = one upstroke and one downstroke)
UltraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 in. (152 mm)/cycle
HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.6 in. (193 mm)/cycle
Fluid viscosity range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50-20,000 cps (heavier viscosities can be mixed with use
of optional heaters, heated hoses, and hardware)
Fluid filtration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 mesh (238 micron) standard
Maximum fluid working pressure
2.5:1 UltraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 psi (1.7 MPa, 17 bar)
24:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . 2400 psi (16 MPa, 166 bar)
34:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . 3400 psi (23 MPa, 234 bar)
47:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . . 4700 psi (32 MPa, 324 bar)
Meter-based systems . . . . . . . . . . . . . . . . . . . . . 4000 psi (28 MPa, 280 bar)
Air supply pressure range. . . . . . . . . . . . . . . . . . . . . . . . . 60-110 psi (420-800 kPa, 4.2-8 bar)
Maximum air consumption at 100 psi (0.7 MPa, 7 bar)
2.5:1 UltraMix . . . . . . . . . . . . . . . . . . . . . . . . . . .
10.8 scfm at 1 gpm (0.30 m
3
/min at 3.8 lpm)
24:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . .
40.5 scfm at 1 gpm (1.13 m
3
/min at 3.8 lpm)
34:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . .
54.7 scfm at 1 gpm (1.53 m
3
/min at 3.8 lpm)
47:1 HydraMix . . . . . . . . . . . . . . . . . . . . . . . . . . .
63.0 scfm at 1 gpm (1.76 m
3
/min at 3.8 lpm)
Ambient temperature range
Operating. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32-104° F (0-40° C)
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30-160° F (–1-71° C)
* Minimum flow rate is dependent on the material being sprayed and mixing capability. Test your material for spe-
cific flow rate.