Graco 309909H Music Mixer User Manual


 
Pressure Relief Procedure
309909H 7
Pressure Relief Procedure
Fluid Manifold to Gun
WARNING
Relieve pressure from fluid manifold to gun whenever
you stop spraying and before servicing gun or remov-
ing spray tip.
In addition, relieve pressure from pump to fluid mani-
fold at end of day and before cleaning, checking, or
servicing pump, manifold, or fluid line accessories or
transporting equipment.
Read warnings, page 5.
1. Engage trigger lock.
2. Press .
3. Disengage trigger lock.
4. Hold a metal part of the gun firmly to a grounded
metal pail. Trigger gun to relieve pressure.
5. Engage trigger lock.