SYNTHESIZER
instrum& containing improvements made after the printing o? the manual.
To ufic this supplement:
Make all ERRATA corrections
Make all appropriate Serial “umber related changes indicated in the tables below.
1 through 6
ERRATA
Pa@ 1.4, Paragraph 1.42:
Add: If the instrument rack mounting slides are to be mounted in a standard &LA. rack, then B” adapter
(HP part number 1494.0023) is needed. The slides without the adapter ca” be directly mounted in
the Hewlett-Packard system enclosures.
1 through 10
CPage 4-14, PROCEDURE, step 4:
Change i” the last sentence 0.17 Vrms to 0.017 Vrms.
) Page 4-23, Paragraph 4.23, DESCRIPTION:
Change in the first sentence, 100 MHz OUT to 10 MHz OUT.
Page 5.9, PROCEDURE, Step 7 (Table of A3AlA2L4 Inductor Values):
Change the HP part number of the .68 pH inductor to 9140-0141.
Ic Page R-43, Figure S-35, (Service Sheet 3~A2):
Change in lower right comer, the off page connection to
CE) 9”AS.
Page 8.51, Figure 8-47 (Service Sheet 7.A2):
Delete, on A2AlOU25, the
connections
between pins 1 and 2, 3 and 4, 5 and 6,7 and 12. Show pins 2,4,5,
a”d 1.2 as no connection (NC).
27 March
8 Pages