Plantronics DJM-3000 DJ Equipment User Manual


 
19
<DRB1314>
BPM COUNTING
Using the Manual Mode to Count BPM
7 When BPM cannot be counted in AUTO BPM mode:
If auto BPM counting is not possible, use the TAP switch
for manual input.
÷ When the TAP switch is pressed in time to the music’s
beat, the light in the BPM counter range display will
turn off and manual mode will go into effect.
÷ The BPM value input with the TAP switch will be
displayed on the Effect parameter/BPM display’s
counter (lower side), and the BPM display’s counter
(upper side) will turn off.
÷ To return to AUTO BPM mode, press the BPM counter
range selector switch and set the counter range.
7 When BPM cannot be counted during delay, echo,
auto pan, auto trans, filter and flanger operations
(pages 14 and 15):
If BPM cannot be counted for more than 2 seconds during
effect operations, the BPM display’s counter (upper side)
will flash. In such a case, change the Effect selector
switch to AUTO BPM and use the TAP switch for manual
input.
÷ After the BPM value input via the TAP switch has been
displayed on the Effect parameter/BPM display’s
counter (lower side) and the Effect selector switch
restored to the original effect, the BPM value input will
be displayed on the BPM display’s counter (upper side).
If you already know the BPM for a track, you can set the
BPM input without using the “TAP” input.
÷ Change the Effect selector switch to AUTO BPM and
press the BPM counter range selector switch and both
BPM counter range displays (70-139 BPM and 91-180
BPM) will turn off.
÷ If the Effect PARAMETER 1 control (TIME) is turned,
the Effect parameter/BPM display’s counter (lower
side) will display the BPM, with adjustment possible
from the first digit.
Turning the PARAMETER 1 control while pressing the
TAP switch makes it possible to adjust the BPM from
the first decimal place.
When the BPM value has been set and the Effect
selector switch restored to the original effect, the BPM
value set will be displayed on the BPM display’s
counter (upper side).
BPM display
Effect parameter/
BPM display
Counter
Counter
BPM counter range
selector switch
BPM counter range
displays