Sound Performance Lab 9631 DJ Equipment User Manual


 
12
Spectralizer
Control Elements
If you want to apply various presets depress APPLY for one
second. The A
PPLY LED starts to flash indicating that the APPLY
mode is activated. You can step through the preset list with UP
and DOWN. Once you have a preset that you want to apply
depress A
PPLY again. The APPLY LED goes out indicating that the
preset is applied.
In case you want to quit the APPLY mode without applying the
new preset simply press S
TORE.
To increase operation safety it is impossible to apply presets
by simply depressing UP or DOWN. The UP and DOWN status-
LEDs will not flash indicating that the input is not accepted. You
have to depress S
TORE or APPLY for one second in order to
activate the U
P and DOWN buttons.
Depressing S
TORE and APPLY simultanouesly for about one
second gets you into a hardware dialogue, called I
NFO. The LC-
display shows status informations of the digital data stream.
With U
P/DOWN you will jump from one page to the next or
previous. If a selection is provided use A
PPLY to select.
1. Software version and date
2. Selecting inputs:
The S
PECTRALIZER automatically searches for an input signal. If
both inputs are connected the AES/EBU input will be selected
first. If you want to select the S/P-DIF input you have to call up
the I
NFO pages.
AES/EBU input detected
or:
no AES/EBU input detected
Press A
PPLY (if AES/EBU is detected):
AES/EBU input with wordclock detected
Applying a preset:
Depress APPLY for1 sec.,
LED flashes;
use U
P/DOWN to select
preset no.;
depress A
PPLY again,
LED goes out
Operation safety:
Presets can not be changed
by accident
Info
12