TC electronic SDN BHD NM-1 Guitar User Manual


 
LFO Trigger
Every time the NOVA Modulator is switched on using
the ON/OFF switch, the LFO is re-triggered. This is a
nice feature that allows you e.g. to sync the tempo of a
Tremolo to the tempo of a song and to make sure that
the sound is “spot-on” all the time.
Example:
Bypass the NOVA Modulator.
Select the Tremolo effect for Engine A and activate
Engine A (the EFFECT switch LED is lit).
Select e.g. 1/8 as subdivision by setting the
TIME/FILTER knob within this interval:
Tap the tempo of the song in quarter-notes using
the TAP TEMPO switch.
Press ON/OFF in tempo, e.g. on the count of
“one”.
The LFO trigger works on all effects. You can
e.g. set a Phaser to start at its lowest point
and peak on the next “one” count.
ADDITIONAL FEATURES
27