Yamaha 01V96 Musical Instrument User Manual


 
244 Chapter 19—Other Functions
01V96 Version 2—Owner’s Manual
Calibrating the Faders
The 01V96 motorized fader positions may shift over time depending on the operating con-
ditions and environment. You can correct the shifted faders using the Calibration function.
1 Make sure that the power to the 01V96 is turned off.
2 Press and hold down the [ENTER] button, then turn on the POWER ON/OFF
switch.
After a while, the following calibration window appears.
3 Make sure that “1 FADER MOVE & FADER POSITION” is selected, then press
[ENTER].
To adjust only the motor fader movement, use the cursor buttons to select “2 FADER
MOVE ONLY,” then press [ENTER].
To adjust only the fader position, use the cursor buttons to select “3 FADER POSITION
ONLY,” then press [ENTER]. Proceed to Step 5.
To cancel the calibration operation, use the cursor buttons to select “4 QUIT,” then press
[ENTER]. The 01V96 starts in normal mode.
4 The calibration operation begins, adjusting the motor fader movement, and
the 01V96 displays a message that indicates the calibration operation is in
progress.
The calibration operation takes about two minutes. DO NOT touch the faders during the
operation.