Yamaha CL3 DJ Equipment User Manual


 
I/O device and external head amp
V1.7 Supplementary Manual
14
If the green indicator is flashing, the unit is the clock master.
If the green indicator is lit, the unit is the clock slave and the clock is synchronized.
Information Messages
The status is shown by the lit/flashing state of the indicator.
If the orange [SYNC] indicator is unlit, the unit is operating normally.
If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed.
Improvements in I/O device settings
When mounting an I/O device on the Dante audio network, the settings and indications have been
improved so that the units can be differentiated by their device type.
The following device labels are detected as supported devices.
Y###-**********
# is a three-digit hexadecimal number (000–FFF) consisting of the digits 0–9 and the uppercase
characters A–F
* indicates any desired character (alphabetical uppercase or lowercase, numerals, or - (hyphen)
may be used)
Up to 31 characters including the ‘Y’ are supported.
The DEVICE LIST field of the DEVICE SELECT popup window shows the device label and device type.
SYNC Indicators Description Possible Solution
A non-GbE-compatible device
is connected.
When transferring audio via Dante,
use device that supports GbE.
The SECONDARY connector
has taken over
communications during
redundant network operation.
Check the circuit connected to the
PRIMARY connector.
An abnormality has occurred
on the circuit connected to the
SECONDARY connector
during redundant network
operation.
Check the circuit connected to the
SECONDARY connector.
SYNC Indicators Description Explanation
Synchronization is occurring.
Please wait until the unit synchronizes
completely. It may take up to
45 seconds to synchronize completely.
(If the DIP switches of an R-series unit
are set to REFRESH, synchronization
will not be completed until the CL
series unit that is set to “with RECALL”
has started up.)
The unit is functioning
correctly as the word clock
master.
The unit is operating as the word clock
master.
The unit is functioning
correctly as the word clock
slave.
The unit is operating as the clock slave
and the clock is synchronized.
Light
Light
or
flash
Flash
Light
or
flash
Flash x2
Light
or
flash
Light
Flash
Light