Internal Design of the CP5 & CP50
Reference
Left & Right Parts
[VOICE]
[PRE-AMP]
[MOD-FX]
[PWR-AMP] (CP5 only)
[LEFT1]/[LEFT2]/[RIGHT1]/
[RIGHT2] (CP5)
[LEFT]/[RIGHT] (CP50)
[COMMON]
Song Setting Area
[SONG SETTING]
[RECORD]
TRACK Part
[TRACK]
MIC INPUT Part
[MIC INPUT] (CP5 only)
Settings for All Parts
[REVERB]
Settings for All Performances
[MASTER COMPRESSOR]
[UTILITY]
[FILE]
Appendix
29 CP5/CP50 Reference Manual
5 PortaSw
(Portamento Switch)
This parameter is used to turn the portamento effect on or off for the current
part.
Setting values: on or off
Time (Portamento Time) This parameter is used to set the amount of time it takes for portamento
pitch sweeps with the current part.
Setting values: 0 to 127
Mode (Portamento Mode) This parameter is used to specify how the current part’s playing style will
affect the way in which portamento is applied.
Setting values: fingr (Finger mode) or full (Full mode)
fingr
Portamento is only applied when you play legato (i.e., playing the next note
before releasing the previous one).
full
Portamento is applied to all notes.
6 F.Cutof (Filter Cutoff) The term “cutoff frequency” is used to describe the center frequency at
which a filter cuts unwanted frequencies. By setting the cutoff frequency,
you can change the way in which the filter affects the sound of the part.
This parameter is used to increase or decrease the cutoff frequency relative
to that set for the current part.
Setting values: -64 to +0 to +63
F.Reso (Filter Resonance) This parameter is used to increase or decrease the filter resonance relative
to that set for the current part.
Setting values: -64 to +0 to +63
7 EGAtk (AEG Attack Time)
EGDcy (AEG Decay Time)
EGRel (AEG Release
Time)
These parameters are used to adjust the attack, decay, and release times
for the part’s amplitude envelope generator. The higher the value set, the
longer it will take for the amplitude to reach the next level (i.e., the slower
the change in volume).
Setting values: -16 to +16
EGAtk (AEG Attack Time)
Sets the amount of time it takes for the amplitude to reach its maximum
level after a key is played.
EGDcy (AEG Decay Time)
Sets the amount of time it takes for the amplitude to drop to the decay level
after reaching its maximum.
EGRel (AEG Release Time)
Sets the amount of time it takes for the amplitude to drop to zero after the
key is released.
NOTE The EGDcy and EGRel settings can also be adjusted using the Decay
and Release parameters (page 13) from the Pre-Amplifier block.
8 NoteLimit (Note Limits) These parameters are used to define a keyboard section for the current
part. Specifically, Knob 1 is used to set the lowest note in the section; Knob
2 is used to set the highest.
Setting values: C-2 to G8
Page
On-screen name
(and full name)
Description
0
Decay
level
Amplitude
Attack
level
Decay
time
Release
time
Attack
time
Key played (Note On) Key released (Note Off)
Time