Yamaha i88X Musical Instrument User Manual


 
English
21
LED Indicators
When you press and hold down the [SELECT] switch for one second or longer, the MONI-
TOR/Sampling Rate indicator for the current operating sampling frequency (44k, 48k, 88k, or
96k) flashes red.
Indicators Status Meaning
ACTIVE Steady blue The i88X is operating normally as an mLAN device.
Off An error has occurred during mLAN operation.
MASTER CLOCK INT Steady green The i88X is using the INTERNAL sampling frequency of
44.1 kHz.
ADAT Steady green The i88X is locking to the wordclock master (ADAT).
Flashing green The i88X is not locking to the wordclock master
(ADAT).
mLAN Steady green The i88X is locking to the wordclock master (ADAT).
Flashing green The i88X is not locking to the wordclock master
(ADAT).
MONITOR
/Sampling Rate
1/2 (44k) Steady red CH 1&2 are selected for monitoring output.
Flashing red The i88X is operating with a sampling frequency of
44.1 kHz.
3/4 (48k) Steady red CH 3&4 are selected for monitoring output.
Flashing red The i88X is operating with a sampling frequency of
48 kHz.
5/6 (88k) Steady red CH 5&6 are selected for monitoring output.
Flashing red The i88X is operating with a sampling frequency of
88 kHz.
7/8 (96k) Steady red CH 7&8 are selected for monitoring output.
Flashing red The i88X is operating with a sampling frequency of
96 kHz.
DIGITAL Steady red DIGITAL is selected for monitoring output.
PEAK Steady red The analog input signal has reached the peak level.
NOTE