NOTE:
1 By default (factory settings) the instrument ordinarily
functions as a 16-channel multi-timbral tone generator,
and incoming data does not affect the panel voices or
panel settings. However, the MIDI messages listed
below do affect the panel voices, auto accompaniment,
and songs.
MIDI Master Tuning
System exclusive messages for changing the
Reverb Type and Chorus Type.
2 Messages for these control change numbers cannot be
transmitted from the instrument itself. However, they
may be transmitted when playing the accompaniment,
song or using the Harmony effect.
3 Exclusive
<GM System ON> F0H, 7EH, 7FH, 09H, 01H, F7H
This message automatically restores all default set-
tings for the instrument, with the exception of MIDI
Master Tuning.
<MIDI Master Volume> F0H, 7FH, 7FH, 04H, 01H, ll,
mm, F7H
This message allows the volume of all channels to
be changed simultaneously (Universal System
Exclusive).
The values of “mm” is used for MIDI Master Volume.
(Values for “ll” are ignored.)
<MIDI Master Tuning> F0H, 43H, 1nH, 27H, 30H, 00H,
00H, mm, ll, cc, F7H
This message simultaneously changes the tuning
value of all channels.
The values of “mm” and “ll” are used for MIDI Master
Tuning.
The default value of “mm” and “ll” are 08H and 00H,
respectively. Any values can be used for “n” and “cc.”
<Reverb Type> F0H, 43H, 1nH, 4CH, 02H, 01H, 00H,
mmH, llH, F7H
mm : Reverb Type MSB
ll : Reverb Type LSB
Refer to the Effect Map (page 84) for details.
<Chorus Type> F0H, 43H, 1nH, 4CH, 02H, 01H, 20H,
mmH, llH, F7H
mm : Chorus Type MSB
ll : Chorus Type LSB
Refer to the Effect Map (page 84) for details.
4 When the accompaniment is started, an FAH message
is transmitted. When accompaniment is stopped, an
FCH message is transmitted. When the clock is set to
External, both FAH (accompaniment start) and FCH
(accompaniment stop) are recognized.
5 Local ON/OFF
<Local ON> Bn, 7A, 7F
<Local OFF> Bn, 7A, 00
Value for “n” is ignored.
Effect map • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
* When a Type LSB value is received that corresponds to
no effect type, a value corresponding to the effect type
(coming the closest to the specified value) is automati-
cally set.
* The numbers in parentheses in front of the Effect Type
names correspond to the number indicated in the dis-
play.
REVERB
CHORUS
TYPE
MSB
TYPE LSB
01 2 8 1617 18 19 20
0 No Effect
1 (01)Hall1 (02)Hall2 (03)Hall3
2 Room (04)Room1 (05)Room2
3 Stage (06)Stage1 (07)Stage2
4 Plate (08)Plate1 (09)Plate2
5...127 No Effect
TYPE
MSB
TYPE LSB
01 2 8 1617 18 19 20
0...63 No Effect
64 Thru
65 Chorus (2)Chorus2
66 Celeste (1)Chorus1
67 Flanger (3)Flanger1 (4)Flanger2
68...127 No Effect