2 –Pump 18-Station Controllers Chapter 4: Operation 25 of 44
Reviewing Pump Status
The “Pump Status” screen is the counterpart of the “Station Status” screen. To reach the
“Pump Status” screen, touch the MENU button. Once in the Main Menu, touch PUMP
STATUS. The “Pump Status” screen appears.
Figure 14: “Pump Status” Screen During Operation
The status of each pump is coded and has a label indicating its’ status in the bottom-left of the
button.
The following table explains the status represented by each icon at the Station Status screen.
Icon Label Description
Offline Pump is not enabled. The controller ignores any alarms.
Ready Pump is off, waiting for demand from a station.
Idle Pump is on, waiting for demand from a station. If there is no
demand before the end of the auto shutdown delay, the pump
will turn off.
Convey Pump is conveying material to a station.
Alarm Pump is in alarm.
Critical Pump is in critical alarm. The controller has disabled the pump
until the alarm is cleared.
Ramping
Up/Down
Pump is in process of starting or stopping.
Additional basic information about each pump, including configuration settings and the
number of hours the pump has been running, is available at the “Pump Setup” screen. For
details on configuration settings, see page 37. For details on the hour meter, see page 30.