A SERVICE OF

logo

Chapter 2 Installing ReadySystem 1U Options
ReadySystem 1U Users Guide 13
2. Disconnect the coaxial power cable from the DC IN connector of the I/O panel.
3. Remove any of the six screws still holding the top cover to the ReadySystem. See Figure 2-3.
4. Slide the top cover to the rear and lift it up and away from the ReadySystem.
Set aside the top cover for later re-installation.
5. If you have not made the necessary changes to the ReadyBoard, including changing the
SODIMM, do so now before continuing.
Once the ReadyBoard is installed into the ReadySystem enclosure, you will not be able to access
the SODIMM socket on the ReadyBoard.
Refer to Removing the SODIMM and Installing the SODIMM procedures.
6. Move the internal cables out of the way to allow installation of the ReadyBoard. See Figure 2-6.
If you did not remove the two USB cables (USB 2 & USB 3) from the enclosure to remove
the ReadyBoard, you need to do so before installing the ReadyBoard back into the enclosure.
If necessary, for greater access to the internal space of the ReadySystem, disconnect any cables
between the +5 volt regulator and the internal parts of the ReadySystem. See Figures 2-4 & 2-6.
Refer also to the respective ReadyBoard QuickStart Guide for more cable removal information.
CAUTION To prevent damage to the static sensitive components on the
ReadyBoard, ensure you follow good Electrostatic Discharge
principles. Components on the ReadyBoard are sensitive to static
electricity and can be easily damaged by improper handling. Do the
following when handling the ReadyBoard:
Always use an anti-static wrist/ankle strap and a grounding mat.
Before you handle the ReadyBoard, touch a grounded, unpainted
metal surface to discharge any static electricity.
RdySy1U_10a
Audio In/Out
Cable
Power Switch Cable
to ReadyBoard
Power On
Cable to
ReadyBoard
IDE Cable
Enclosure
Fan Cables
DC In Cable to
Regulator Board
+5VDC Regulator
Board
Power In Cable
to ReadyBoard
Figure 2-6. Internal Cables Shown Separated