138
Modem 34336
Primary Options:
addr
999 999
Group Unit
address address
Figure C-2. How to move the cursor
in the SETUPS screen using the
pushbuttons.
Dial Line Options:
dial
11111002210
Pulse dialing rate (pulses per sec): 0=10, 1=20
Wait for carrier (sec): 0=30, 1=45, 2=60, 3=75
T1 timer (sec): 0=0, 1=0.3, 2=0.8, 3=1.6, 4=3.0
Carrier detect level, dial (dBm): 0=-26,1=-33, 2=-43
TX level, dial: 0=permissive, 1=programmable
Disconnect, RTS (sec): 0=off, 1=140, 2=120. . . 7=20
Disconnect, line current: 0=disable, 1=enable
Disconnect, carrier: 0=disable, 1=enable
Disconnect, TX space: 0=disable, 1=enable
Disconnect, RX space: 0=disable, 1=enable
Auto-answer: 0=disable, 1=enable
EIA INTERFACE OPTIONS:
e i a
010211000
Test mode: 0=normal, 1=true
Remote digital loopback test: 0=disable, 1=enable
Analog loopback test: 0=disable, 1=enable
CTS: 0=normal, 1=follow RTS, 2=true, 3=on
Carrier detect: 0=normal, 1=true, 2=toggle
DSR: 0=true, 1=normal, 2=crossover
DTR: 0=normal, 1=true
Increase
the value of
the blinking
character
by one