ICP-CC488 | Installation Guide | 10.0 Dialer Reporting Formats EN | 46
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Table 43: Point ID Codes
Point ID Event Description Event Code Explanation Section
Zones 1 to 8 Burglary Zone 130 Burglary 14.3.2
Medical Zone 100 24-Hour Medical 14.3.2
Panic Zone 120 24-Hour Panic 14.3.2
Hold-Up Zone 122 24-Hour Hold-Up 14.3.2
Tamper Zone 137 24-Hour Tamper 14.3.2
Burglary Zone 133 24-Hour Burglary 14.3.2
Fire 110 24-Hour Fire 14.3.2
User Specific 1 to 16 Open/Close Report 401
Opening – User #
Closing – User #
15.14
User Specific 1 to 16 Open/Close Report Partitioned 402
Opening – User #
Closing – User #
15.14
User Specific 1 to 16 Partial Close Report 456 Closing – User # 12.2
040 AC MAINS Fail 301 AC Power 15.22
031 Low Battery 309 Battery Test Failure 15.24
User Specific 1 to 16 Codepad Duress 121 Duress Alarm 15.15
041 Codepad Panic 120 Panic Alarm 15.16
046 Codepad Fire 110 Fire Alarm 15.17
045 Codepad Medical 100 Medical Alarm 15.18
042 Code Retry Limit Exceeded 421 Access Denied 15.26
044 Test Report – Automatic 602 Test Report 15.28
047 Test Report After Siren Reset 602 Test Report 18.5
Zone Specific 1 to 8 Sensor Self Test Failure 307 Sensor Watch 15.5
Zone Specific 1 to 8 RF Device Supervision 15.8
Zone Specific 1 to 8 Trouble 380 Sensor Trouble 15.4
00 AUX Power Supply Fail 300 System Trouble 15.20
User Specific Walk Test 607 Walk Test Mode 15.2
Zone Specific 1 to 8 Tamper 144 Zone Tamper 15.1
Zone Specific 1 to 8 RF Low Battery 384 RF Low Battery 15.9
001 RF Receiver Fail 355 RF Receiver Jamming 15.10
002 RF Receiver Tamper Switch 15.10
003 RF Receiver Failure 15.10
Zone Specific 1 to 8 Bypass 573 Zone Bypass 15.3
Zone Specific 1 to 8 Bypass 572 24-Hour Zone Bypass 15.3
Zone Specific 1 to 8 Bypass 571 24-Hour Fire Zone Bypass 15.3