A SERVICE OF

logo

ICP-CC488 | Installation Guide | 14.0 Zone Information EN | 58
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Figure 13: Split EOL Resistors Using Two N/O
Contacts
2
3
1
4
5
6 7
8 8
1 – +12 V
2 – Zone Input
3 – Zone
4 – EOL 3k3
5 – EOL 6K8
6 – EOL 1K5
7 – EOL 4K7
8 – N/O
14.3 Zone Programming
The programming information for each zone is
stored in seven locations divided into three groups.
The first three locations determine how the zone
operates, the next two locations set up a number of
zone options, and the last two locations store the
dialer reporting information for the zone.
Zone Operating Information
These locations store the Zone Type (for example,
Delay-1, Instant, or 24-Hour), the Zone Pulse Count,
and the Zone Pulse Count Time. The Zone Pulse
Count specifies the number of times the zone must
activate within the time specified in the Zone Pulse
Count Time. Refer to Sections 14.3.2 Zone Types,
14.3.3 Zone Pulse Count, and 14.3.4 Zone Pulse Count
Time on pages 59 through 61 for more information.
Zone Options
These two locations allow you to select from a
number of options. Refer to Sections 14.3.5 Zone
Options 1 on page 61 and 14.3.7 Zone Options 2 on
page 63 for more information.
Zone Reporting Information
This information includes the locations for the Zone
Report Code and the Zone Dialer Options.
The Zone Report Code determines if the control
panel sends Alarm Reports for the zone. Refer to
Section 14.3.8 Zone Report Code on page 64 for more
information.
The Zone Dialer Options location enables you to
specify how a zone reports to a base station receiver.
Refer to Section 14.3.9 Zone Dialer Options on page 64
for more information.
14.3.1 ICP-CC488 Zone Defaults
Location
267 to 378
Location Default
Zone #01 (Default = Delay–1)
Zone Type 267 2
Zone Pulse Count 268 0
Zone Pulse Count Time 269 0
Zone Options 1 270 1
Zone Options 2 271 14
Report Code 272 1
Dialer Options 273 1
Zone #02 (Default = Handover)
Zone Type 274 1
Zone Pulse Count 275 0
Zone Pulse Count Time 276 0
Zone Options 1 277 1
Zone Options 2 278 14
Report Code 279 1
Dialer Options 280 1
Zone #03 (Default = Handover)
Zone Type 281 1
Zone Pulse Count 282 0
Zone Pulse Count Time 283 0
Zone Options 1 284 1
Zone Options 2 285 14
Report Code 286 1
Dialer Options 287 1
Zone #04 (Default = Handover)
Zone Type 288 1
Zone Pulse Count 289 0
Zone Pulse Count Time 290 0
Zone Options 1 291 1
Zone Options 2 292 14
Report Code 293 1
Dialer Options 294 1
Zone #05 (Default = Instant)
Zone Type 295 0
Zone Pulse Count 296 0
Zone Pulse Count Time 297 0
Zone Options 1 298 1
Zone Options 2 299 14
Report Code 300 1
Dialer Options 301 1
Zone #06 (Default = Instant)
Zone Type 302 0
Zone Pulse Count 303 0
Zone Pulse Count Time 304 0
Zone Options 1 305 1
Zone Options 2 306 14
Report Code 307 1
Dialer Options 308 1