![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/b/81/b81ecf07-f227-4c3c-bc4c-801405d13b12/b81ecf07-f227-4c3c-bc4c-801405d13b12-bg3a.png)
56 Printer operation Q1860-90918
EIO menu (HP LaserJet 5100tn and 5100dtn printers)
EIO (enhanced input/output) menus depend on the particular accessory product that is installed
in an EIO slot of the printer. If the printer contains an HP Jetdirect print server EIO card, you can
configure basic networking parameters using the EIO Menu. These and other parameters can
also be configured through HP Jetdirect or the HP Jetdirect EIO Web server.
Table 22. EIO menu for networked printers
Item Values Explanation
CFG NETWORK=NO NO
YES
NO
: The Jetdirect menu is not available.
YES: The Jetdirect menu appears.
NOVELL=ON ON
OFF
Select whether the IPX/SPX protocol stack (in Novell
NetWare networks, for example) is enabled (on) or disabled
(off).
DLC/LLC=ON ON
OFF
Select whether the DLC/LLC protocol stack is enabled (on)
or disabled (off).
TCP/IP=ON ON
OFF
Select whether the TCP/IP protocol stack is enabled (on) or
disabled (off).
ATALK=ON ON
OFF
Select whether the Apple EtherTalk protocol stack is enabled
(on) or disabled (off).
CFG IPX/SPX=NO NO
YES
NO
: The IPX/SPX menu is not available.
YES: The IPX/SPX menu appears. In the IPX/SPX menu,
you can specify the frame-type parameter that is used on
your network. The default is AUTO, to automatically set and
limit the frame type to the one detected.
For Ethernet cards, frame-type selections are EN_8023,
EN_II, EN_8022, and EN_SNAP.
For token ring cards, frame type selections are TR_8022 and
TR_SNAP.
In the IPX/SPX menu for token ring cards, you can also
specify NetWare Source Routing parameters, which are SRC
RT_AUTO (default), OFF, SINGLE R, or ALL RT.
CFG TCP/IP=NO NO
YES
NO
: The TCP/IP menu is not available.
YES: The TCP/IP Menu appears. In the TCP/IP menu, you can
specify BOOTP=YES or BOOTP=NO for TCP/IP parameters to
be automatically loaded from a bootp or DHCP server when
the printer is turned on. If you specify
BOOTP=NO and
DCHP=NO, you can manually set selected TCP/IP parameters
from the control panel. You can manually set each byte of the
IP address (IP), Subnet Mask (SM), Syslog Server (LG), and
Default Gateway (GW). For example:
If the Syslog Server IP address is left blank, the printer will
still work. Also, you can manually set the timeout time
period.
192.0.0.192
Byte 1
Byte 2
Byte 3
Byte 4
www.GovTechMedia.com