![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/5/ab/5abdb5bd-1c0a-4842-85ef-70d81c5b4833/5abdb5bd-1c0a-4842-85ef-70d81c5b4833-bg17.png)
19
NOTE: If the display flashes “Er”, the password was incorrect, and the process to enter the password
must be repeated.
Use the s and t buttons to scroll to the desired parameter number. In the example below, Parameter
19 is being displayed, which is the ACCELERATION TIME of the drive:
Once the desired parameter number is found, press the Mode button to display the present parameter
setting. The upper right-hand decimal point will begin blinking, indicating that the present parameter
setting is being displayed, and that it can be changed by using the s and t buttons.
Use s and t to change setting
(example setting changed to 30)
Press Mode to store new setting
Pressing the Mode will store the new setting and also exit the PROGRAM mode. To change another
parameter, press the Mode key again to re-enter the PROGRAM mode (the parameter menu will be
accessed at the parameter that was last viewed or changed before exiting). If the Mode key is pressed
within two minutes of exiting the PROGRAM mode, the password is not required access the parameters.
After two minutes, the password must be entered in order to access the parameters again.
Use s and t to scroll to the desired
parameter number
Press Mode to display present parameter
setting (present example setting is 15)
Right decimal point blinks